LWGY Series Turbine Flow Meter
|
Liquid Turbine Flow Meter
|
Description
Turbine Flow Meter is a main type of impeller flow meter
including the Anemoscope and Water meter. It is made up of
Sensor and Conversion-Show. The Sensor reacts to the
average velocity of fluid with multi-blades rotor so as to
speculating the flow value and the accumulative flow value.
|
Technical Parameter
|
Nominal
Diameter(mm) &Connection
|
4,6,10,15,20,25,32,40 (tread connection) 15,20,25,32,40 (tread and flange connection) 50,65,80,100,125,150,200 ( flange connection)
|
Accuracy Class
|
Regular accuracy ±1%R, ±0.5%R, Highest accuracy ±0.2% R
|
Measurement Range Rate
|
1:10,1:15,1:20
|
Instrument material
|
304 stainless steel; stainless steel; etc.
|
Medium Temperature(℃)
|
-20 ~ +120 ℃
|
Ambient Conditions
|
Temperature:-10~+,
Relative Humidity: 5%~90%
Atmosphere Pressure:86~106Kpa
|
Signal Output
|
Sensor: pulse frequency signal,
low level≤0.8V
high level≥8V.
Transmitter: current signal
4~20mA DC
two wires
|
Supply Power
|
Sensor: +12V DC, +24V DC (option)
Transducer: +24V DC
Scene display type meter: 3.2V Lithium cell
|
Signal Transmission Line
|
STVPV 3×0.3 (three wires), 2×0.3(two wires)
|
Transmission Distance
|
≤1000m
|
Signal Line Interface
|
Internal thread M20×1.5
|
Explode-proof Class
|
ExdIIBT6
|
Protection Class
|
IP65
|
|
Turbine Meter with Pulser
|
Sanitary Turbine Meter
|
I. Measurement range and Working pressure for liquid
|
Diameter (mm)
|
|
Expanding Flow Rate(m3/h)
|
Regular TolerancePressure(Mpa)
|
Special TolerancePressure(Mpa)
|
DN4
|
0.04—0.25
|
0.04—0.4
|
6.3
|
12, 16, 25
|
DN6
|
0.1—0.6
|
0.06—0.6
|
6.3
|
12, 16, 25
|
DN10
|
0.2—1.2
|
0.15—1.5
|
6.3
|
12, 16, 25
|
DN15
|
0.6—6
|
0.4—8
|
6.3, 2.5(flange)
|
4.0, 6.3, 12, 16, 25
|
DN20
|
0.8—8
|
0.45—9
|
6.3, 2.5(flange)
|
4.0, 6.3, 12, 16, 25
|
DN25
|
1—10
|
0.5—10
|
6.3, 2.5(flange)
|
4.0, 6.3, 12, 16, 25
|
DN32
|
1.5—15
|
0.8—15
|
6.3, 2.5(flange)
|
4.0, 6.3, 12, 16, 25
|
DN40
|
2—20
|
1—20
|
6.3, 2.5(flange)
|
4.0, 6.3, 12, 16, 25
|
DN50
|
4—40
|
2—40
|
2.5
|
4.0, 6.3, 12, 16, 25
|
DN65
|
7—70
|
4—70
|
2.5
|
4.0, 6.3, 12, 16, 25
|
DN80
|
10—100
|
5—100
|
2.5
|
4.0, 6.3, 12, 16, 25
|
DN100
|
20—200
|
10—200
|
2.5
|
4.0, 6.3, 12, 16, 25
|
DN125
|
25—250
|
13—250
|
1.6
|
2.5, 4.0, 6.3, 12, 16
|
DN150
|
30—300
|
15—300
|
1.6
|
2.5, 4.0, 6.3, 12, 16
|
DN200
|
80--800
|
40—800
|
1.6
|
2.5, 4.0, 6.3, 12, 16
|
|
II. Measurement range and Working pressure for gas
|
|
|
|
|
|
LWQ
|
25 (1”)
|
0.7—7
|
0.6
|
4.0 Flange or Thread
|
LWQ-25B
|
1.5—15
|
1.0
|
4.0 Flange or Thread
|
LWQ
|
3—30
|
2.0
|
4.0 Flange or Thread
|
LWQ
|
40 (1.5”)
|
4—40
|
2.5
|
4.0 Flange or Thread
|
LWQ-40B
|
8—80
|
3
|
4.0 Flange or Thread
|
LWQ
|
50 (2”)
|
10—100
|
3.5
|
4.0 Flange
|
LWQ-50B
|
15—150
|
4
|
4.0 Flange
|
LWQ-80
|
80 (3”)
|
15—300
|
4
|
1.6 Flange
|
LWQ-100
|
100 (4”)
|
20—400
|
5
|
1.6 Flange
|
LWQ-150
|
150 (6”)
|
50—1000
|
8
|
1.6 Flange
|
LWQ-200
|
200 (8”)
|
100—2000
|
20
|
1.6 Flange
|
LWQ-250
|
250 (10”)
|
150—3000
|
30
|
1.6 Flange
|
LWQ-300
|
300 (12”)
|
200—4000
|
40
|
1.6 Flange
|
|
|
|