M series Positive Displacement Flow Meter

M-50-1 Meter with Register, Strainer & Air Eliminator
|
Characteristics
•Excellent stepless adjusting mechanism allows a micro adjustment of the meter
•High accuracy and repeatability over the widest range of flow; Superior accuracy at constant flow
•Low maintenance, no metal-to-metal contact in measuring chamber, long life service
•Low pressure loss, a true gravity flow meter
•Accuracy regardless of pressure fluctuations, temperature variation, viscosity
•Choice of aluminum, cast iron and stainless steel materials of construction
|
Construction
|
Technical Specification
|
Model
|
M-40-1
|
M-50-1
|
M-50H-1
|
M-80-1
|
M-80H-1
|
M-100-1
|
M-100H-1
|
M-150-1
|
M-150H-1
|
Size
|
40mm /1.5”
|
50mm / 2 "
|
80mm / 3 "
|
100mm / 4 "
|
150mm / 6 "
|
Flow Range
(L/Min)
|
25-250
|
38-380
|
55-550
|
75-750
|
115-1150
|
130-1300
|
170-1700
|
225-2250
|
300-3000
|
Volume/Rev.
|
0.309L
|
0.681L
|
1.839L
|
5.102L
|
9.507L
|
Max.Pressure
|
10Bar/150PSI
|
25Bar/350PSI
|
Accuracy
|
±0.2%
|
Repeatability
|
≤0.05%
|
Standard Measurement
|
Liter / US Gallon/IMP Gallon
|
Viscosity
|
30SSU~1,500,000SSU
|
Note:4"&6" flange available for M-150/6" Meter.
Packaging Data
|
Model
|
M-40-1
|
M-50-1
|
M-80-1
|
M-100-1
|
M-150-1
|
Packaging
|
1 pc/Wooden Case
|
Net Weight
|
23Kgs
|
26Kgs
|
40Kgs
|
70Kgs
|
130Kgs
|
Gross Weight
|
35Kgs
|
38Kgs
|
55Kgs
|
90Kgs
|
155Kgs
|
Size
|
53×48×53cm
|
53×48×53cm
|
58×50×61cm
|
76×64×72cm
|
80×65×79cm
|
Model No. Description

M-80-1 Meter
|

M-80-1 Meter with Register
|

M-80-1 Meter with Register & Strainer
|

M-80-1 Meter with Register, Strainer & Air Eliminator
|

M-150-A-1 Meter with Register
|

M-50-KX-1 Preset Meter with Register, Preset Register,
Preset Valve, Strainer & Air Eliminator
|
|
M-80-G-1 Meter with Register, Strainer,
Air Eliminator & Printer
|
M-50-NX-1 Preset Meter with Register, Preset Register,
Preset Valve, Strainer, Air Eliminator & Printer
|

M-80-KPX-1 Meter with Electronic Register, Strainer,
Air Eliminator & Duel Flow Solenoid Valve
|

M-50-PP-1 Meter with Pulser
|

MA-40-CX-10 LPG Meter with 2-Meter, 2-Pulser,
1- Differential Valve, 1-Strainer, 1- Air Eliminator
|

MA-50-CX-10 LPG Meter with Register, Differential
Valve, Strainer & Air Eliminator
|
Industries
• Automotive;
• Adhesives;
• Agriculture;
• Asphalt ;
• Aviation fueling ;
• Animal feeds; Beverage;
• Cosmetics ;
• Chemical processing;
• Concrete Add mixtures;
• Dairy; Liquid fertilizers;
• Food processing ;
• Fuel oil delivery;
• General industrial;
• Hydrocarbon processing;
• Liquefied gases;
• Lube oils; Marine;
• Paint and varnish;
• Petroleum marketing;
• Petroleum production ;
• Pharmaceutical;
• Printing ink;
• Pulp &paper;
• Refining commercial Solvents;
• Recycling Railroad ;
• Textile.
|
Application
• Refined petroleum products;
• Aviation gasolines and jet fuels;
• A wide variety of products such as: liquid sugars, corn syrup, corn
sweetners, dextrose,fructose, sucrose, maltose, lactose, corn oil,
soy bean oil, cotton seed oil, coconut oil;
• Treated waters (deionized, demineralized, and potable);
• Chlorinated solvents and general solvent metering;
• Acid pH liquids;
• Liquefied petroleum gas(LPG);
• Crude oil, also for heated and/or viscous liquids;
• Oil or water based latex products, polyester resins,
and adhesives (neutral pH), also for metering herbicides and
nitrogen fertilizer solutions;
• Herbicide;
• Sodium hydroxide (caustic) solutions, high sulfur crude oil (LACT
and NOD) and other alkaline pH liquids;
• Abrasive liquids.
|
FL Air Eliminator
Aluminum, cast iron, stainless steel available.
|
FL Air Eliminator
|
FL Air Eliminator with Plate
|
|
GLQ series Strainer
Technical Specification
|
Model
|
Diameter
|
GLQ-50
|
50mm/2"
|
GLQ-80
|
80mm/3"
|
GLQ-100
|
100mm/4"
|
GLQ-150
|
150mm/6"
|
|
GLQ-50 Strainer
|
GLQ-150 Strainer & Air Eliminator
|
Strainer Basket
|
The proper strainer basket to use depends on the different product and its viscosity over the expected range of metering temperature.
|
Strainer Basket
|
Strainer Mesh
|
General Application
|
200M
|
LPG only
|
100M
|
Gasoline, Solvents, LPG
|
80M
|
Gasoline, Solvents
|
40M
|
Heating Oil, Diesel fuel, Light oils
|
20M
|
Motor oils&other viscous products
|
|
LPGX Series Filter & Air Eliminator
|
LPGX Series Filter and Air Eliminator integrates the function of filter and air Eliminator into one body. It not only can filter the solid impurity, but also can expel the gas out the liquid at one time. It can be used to match with many kinds of flow meters to improve the measuring accuracy.
|
LPGX Series Filter & Air Eliminator
|
|
Technical Data
|
Diameter: DN40-200
|
Nominal Pressure:1.6,2.5,4.0,6.4Mpa
|
Fluid Temperature:-30℃~+250℃
|
Press Loss:≤0.03Mpa
|
|
Note: bigger size can be manufactured as per requirement
|
V-80 Piston Valve
|
V & VS series Piston Valves
|
V series Mechanically actuated piston valves are designed for mounting on the meter outlet to completely shutoff the liquid flow with easy operation under any pressure system. The valve can be operated manually or connected via a mechanical linkage to a preset counter on the meter for single stage closure or two-stage closure to eliminate hydraulic shock. The valve is indexable in 90o turn for up & down or side facing outlet. 2",3",4" available for option.
|
Technical Specification
|
Model
|
Diameter
|
Used for Meter
|
Max. Flow Rate L/Min
|
Material
|
V-50
|
1.5"& 2"
|
M-40, M-50, M-50H
|
550
|
Aluminum
|
V-80
|
3"
|
M-80, M-80H
|
1136
|
V-100
|
4"
|
M-100, M-100H
|
2271
|
|
K-80 Check Valve
|
K Series Air Activated Differential Check Valve
|
K Series Air Activated Differential Check Valves are installed at the outlet of the meter, which is designed to stop the flow of liquid whenever air is present to ensure accurate measurement.
|
Technical Specification
|
Model
|
Diameter
|
Used for Meter
|
Max. Flow Rate L/Min
|
Material
|
K-50
|
1.5"& 2"
|
M-40, M-50, M-50H
|
550
|
Aluminum
|
K-80
|
3"
|
M-80, M-80H
|
1136
|
|
V-50-LPG Differential Valve
|
V-50-LPG Differential Valve
|
The differential valve is mounted at the outlet of the meter and connected with the vapor eliminator with the function to shut off the liquid flow whenever vapor occurs in the tube system. The valve maintains sufficient pressure to ensure the high-vapor pressure products, such as LPG & Anhydrous Ammonia (NH3) to be always remained in liquid state. The valve is spring loaded and to fail if closed.
|
Technical Specification
|
Model
|
Diameter
|
Used for Meter
|
Max. Flow Rate L/Min
|
Material
|
Working Pressure
|
V-50-LPG
|
1.5"& 2"
|
M-40, M-50, M-50H
|
760
|
Aluminum
|
350PSI
|
|
Solenoid Valve
Solenoid Plug Valve & Solenoid Air Check Valve
Size:1.5“,2", 3", 4" & 6"
Power:220VC/50Hz or 24VDC
|